Add to Cart
Anesthetic Workstation X50-12.1" TFT touch screen, with rotary knob. Resolution 800 X 600.
Suitable for pediatric and adults
Tidal volume setting Optional 20~1500ml(optional 10-1600ml)
Friendly user interface
Sufficient modes of Ventilation: VCV, PCV, SIMV-V, Manual
Gas supply: O2 , N2O, Air
Optional: SIMV-P , CPAP/PSV , PRVC, SIMV-PRVC, BACKUP , O2 , ETCO2 , AGSS , Suction,AA
6 Tubes flowmeter more accurate and stable, auxiliary flowmeter Gas system, Hypoxic guard system, ORC, O2, Flush
Vaporizer: Selectatec bar support 2 vaporizers
ACGO, 2 Yokes (O2 & N2O)
12.1" TFT touch screen, with rotary knob. Resolution 800 X 600.
System Specifications
System Specifications | |
Description | Technical parameters |
Machine | |
Size | 1410 × 950 × 650 (H × W × D) |
Weight | Approximately 110kg |
Maximum bearing weight of the top cover | 30kg |
Display | |
Type | Color TFT (touch screen) |
Size | 12.1 inches |
Resolution | 600 × 800 pixels |
Brightness | Not adjustable |
LED indication | |
Alarm Indication | 8 (yellow, red, and when the senior and mid-level alarms occur simultaneously, only red flashes on priorty) |
AC power indicator | 1 (green) |
Battery indicator | 2 (green and orange) |
Audio instruction | |
Speaker | Alarm sounds, tone ,volume adjustable,alarm tone meet IEC60601_1_8 standards. |
Control | |
Knobs | 1, Support clockwise / counterclockwise rotation and pressing operation |
Button | 4, Alarm pause, alarm reset, standby, back to the main screen. |
Interface | |
Power supply | An AC power connector Three auxiliary output power interface |
Equipotential | An equipotential ground |
USB | 1 standard USB interface |
Moving means | |
Roller | 4 castors, diameter 125mm |
Brake castors | Two lockable front casters |
Toolbox | |
Drawer | 200 × 392 × 398 (H×W×D) |
Respiratory System | |
Bellows capacity | 1500mL |
Absorber canister capacity | 1500mL |
Connection | Suction / ACGO ports: standard OD 22mm, ID 15mm, tapered connector; Exhalation ports: standard OD 22mm, ID 15mm, tapered connector. Manual breathing bag port: diameter 22cm |
System leaks | The system is not greater than 100ml/min leakage in any mode |
System compliance | The loss due to the system’s internal compliance gas volume (manual mode)as follows: |
Adult mode | ≤ 4 mL / cmH2O, |
pediatric mode | ≤ 3 mL / cmH2O |
Resistance | Inspiratory < 0.6 kPa; Expiratory < 0.6 kPa |
Real-time clock | |
Range | 2000 (00:00) ~ 2100 (23:59) |
Accuracy | ± 1 minute |
Display Resolution | 1 minute / month(at 21±3℃ under the conditions) |
Use the Power | Independent power (Button battery)supply |
Vaporizer | |
Technical Specification | |
Flow range | 0.2-15L/min |
Connector type | Selected compatible, plug in, cage mount |
Dosing methods | Pour-fil, Easy-fil, Quick-fil (Sevoflurane) |
Working environment | |
Working temperature | +15℃ ~ +35℃ |
Relative humidity | ≤93% |
Atmospheric pressure range | 70kPa ~ 106kPa |
Storage temperature | -40℃ ~ +65℃ |
Anesthetic Concentration: | |
0~5.0%: | Isoflurane, Enflurane, Halothane |
0 ~ 8.0%: | Sevoflurane |
Main technical parameters | |
Basic function | Disply:12” TFT, Touch screen Tidal Volum:20-1500ml(optional 10-1600ml) Fresh gas compensation pre-use check, Leakage testing and compliance compensation Electronic PEEP |
Wave form | |
Loop | P-V,V-F,P-F |
Paw-T, Flow-T,V-T | |
Optional | CO2-T ,Pleth ,AG |
Trend | |
24hours | |
Gas supply Pressure Monitoring
| Gauge-Pipeline supply: O2, N2O, Air Optional :gauge-cylinder: O2, N2O(configured with Yoke option ) |
Monitoring Parameter
| Tidal Volume, MV, Frequency, I:E, Airway Pressure , Compliance, Resistance.(optional :EtCO2,FiCO2,PHASEIN gas module for anesthetic agent) |
Application | Adult , pediatric and Infant |
Vaporizer | two position |
Gas supply | O2, N2O, Air |
Alternate O2(safety flow )
| Range:0 to 15 L/min Indicator : flow tube Indicator accuracy :±10% |
Fresh gas flowmeter &mixer (electronic automatic control) | |
O2 | 0~15LPM |
N2O | 0~12LPM |
Air | 0~15LPM |
Flow accuracy | ±10% of setting ±0.1/min |
O2 concentration range | 21% to 100% O2 concentration |
Accuracy | ±5% |
Electronic mitting compensation | 0.5s(10%-90% flow step) |
Compensation | Temperature and atmospheric pressure compensated to standard conditions of 20C and 1013kpa |
Hypoxic guard | Electronic |
FiO2% | O2sensor |
Auxiliary O2 supply | O2 Flow meter (O2: 0~15LPM) (Optional) |
ACGO | Yes(optional) |
Battery | NI-MH battery build in.>90mins |
Yoke | Optional:O2, N2O |
Cycle Absorber | Intergrade, bypass Design, heating system. |
Setting Parameter | |
Description | Parameter |
Tidal Volume | 20~1500 mL(optional 10-1600ml) |
Frequency | 1~100 bpm |
Tinsp | 0.1~10.0s |
I:E | 4:1~1:10 |
Pause | 0~60% |
PEEP | OFF, 3~30 cmH2O |
Psupp | 0~70 cmH2O |
Pressure Control | 5~70 cmH2O |
Flow Trigger | 0.5~20 L/min |
Pressure Trigger | 0~20 cmH2O |
Ramp | 0~2s |
Expiratory Trigger | 5~80% |
Monitoring Parameter | |
Description | Parameter |
Tidal Volume Inspiration | 0~2500 mL |
Tidal Volume Expiration | 0~2500 mL |
MV | 0~60 L/min |
MVspont | 0~60 L/min |
Frequency | 0~100 bpm |
Ratespont | 0~100 bpm |
I:E | 9:1~1:99 |
Ppeak | 0~100 cmH2O |
Pmean | 0~100 cmH2O |
PEEP | 0~100 cmH2O |
Pplat | 0~100 cmH2O |
Pmin | -20~100 cmH2O |
O2% | 15~100% |
Compliance | 0~300 mL/cmH2O |
Resistance | 0~600 cmH2O/(L/s) |
EtCO2 (Optional) | 0~13.3 % |
FiCO2 (Optional) | 0~13.3 % |
Anesthetic agent | Massimo gas module for anesthetic agent |
Flow trigger | 0.5~20L/min |
Pressure trigger | 0~20cmH2O |
Ramp | 0~2s |
Expiratory | 5~80% |
Alarm Parameter | |
Description | Parameter |
Tidal Volume | |
Upper limit | 30~2000 mL |
Lower limit | OFF, 20~1500 mL |
MV | |
Upper limit | 1~99 L |
Lower limit | 0~98 L |
O2% (Optional) | |
Upper limit | 22~100%,OFF |
Lower limit | 20~99% |
Airway Pressure | |
Upper limit | 10~99 cmH2O |
Lower limit | 1~98 cmH2O |
Frequency | |
Upper limit | 1~100 bpm |
Lower limit | 0~99 bpm |
EtCO2 (Optional) | |
Upper limit | 0.1~13.3 % ; |
Lower limit | 0~13.2 %; |
Environment specification | |
Description | Parameter |
Work environment | |
Temperature | 10-40℃ |
humidity | 5~95%,non-condensing |
Environmental Pressure | 50~106kpa |
Storage environment | |
Temperature | -20-55℃ |
humidity | 10~95%,non-condensing |
Environmental Pressure | 50~106kpa |
Power Specifications | |
Description | Parameter |
External AC power | |
Input Voltage | 100 - 240V |
Input Frequency | 50/60Hz |
Input Power | <150 VA |
Internal Battery | |
Number of batteries | A battery pack |
Battery Type | Nimh batteries |
Rated battery voltage | 12VDC |
Battery capacity | 4200mAh |
Shutdown Delay | Less than 10min |
Charging time | 4h |
About us
Beijing Siriusmed Medical Device Co., Ltd is among the top level Manufactures of anesthesia machine and ventilators in China since 2013. Our main products are: Anesthesia machine, vaporizer, ICU Ventilator, neonatal ventilator, and air compressors. With the quality certificates of NMPA, ISO 13485, CE and BGMP, we offer the whole OR & ICU solutions to the world. Right now we established the long term ditributors, OEM & SKD partners in Germany, UK, U.S. India, Brazil, Morocco ... etc more than 80 countries in the world. Welcome to join us for the long term cooperation for our products: anesthesia machine, anestheisa ventilator, vaporizer, ventilator, air compressor and monitors... etc.